Double Stopband Bilayer Photonic Crystal Based Upconversion Fluorescence PSA Sensor - Normandie Université Accéder directement au contenu
Article Dans Une Revue Sensors and Actuators B: Chemical Année : 2021

Double Stopband Bilayer Photonic Crystal Based Upconversion Fluorescence PSA Sensor

Songtao Hu
  • Fonction : Auteur
Hongwei Xu
  • Fonction : Auteur
Bingshuai Zhou
  • Fonction : Auteur
Shihan Xu
  • Fonction : Auteur
Bo Shen
  • Fonction : Auteur
Biao Dong
  • Fonction : Auteur
Ze Yin
  • Fonction : Auteur
Sai Xu
  • Fonction : Auteur
Liheng Sun
  • Fonction : Auteur
Jiekai Lv
  • Fonction : Auteur
Jiahe Wang
  • Fonction : Auteur
Wen Xu
  • Fonction : Auteur
Xue Bai
Lin Xu
  • Fonction : Auteur
Svetlana Mintova
Hongwei Song
  • Fonction : Auteur

Résumé

Precise detection on tumor markers is significant for the early diagnosis on cancer. Upconversion fluorescence probes are ideal for tumor marker sensing, but still subject to bottleneck problems of low emission efficiency/strength. In this work, a novel bilayer of poly(methyl methacrylate) opal photonic crystal (PMMA OPC) with double photonic stop bands was fabricated to match the excitation field and emission field of the upconversion nanoparticles (UCNPs) at the same time, and greatly enhance their upconversion fluorescence intensity. Herein, NaYF4:Yb 3+ ,Er 3+ UCNPs and NaYF4:Yb 3+ ,Er 3+ @NaYF4:Yb 3+ ,Nd 3+ UCNPs with a core-shell structure were employed as a core, which could be excited by 980 nm and 808 nm light, respectively. With the optimized geometry structure, the upconversion emission intensity was enhanced over 150 folds under the excitation of both 808 nm and 980 nm laser. Through the NaYF4/OPC biochip and florescence resonant energy transfer (FRET) sensing strategy, the lowest detection limit of 0.01 ng/mL with good linear relationship was obtained ranging from 0.1 ng/mL to 10 ng/mL. The power density of the pumping light was as low as 1.7 W/cm 2. This enhanced upconversion tumor marker biochip sensor provides a promising and powerful tool for facile early diagnosis on cancer markers.
Fichier principal
Vignette du fichier
Double Stopband Bilayer Photonic Crystal Based Upconvers on Fluorescene PSA Sensor.pdf (1.14 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03016039 , version 1 (02-12-2020)

Identifiants

Citer

Songtao Hu, Hongwei Xu, Bingshuai Zhou, Shihan Xu, Bo Shen, et al.. Double Stopband Bilayer Photonic Crystal Based Upconversion Fluorescence PSA Sensor. Sensors and Actuators B: Chemical, 2021, 326, pp.128816. ⟨10.1016/j.snb.2020.128816⟩. ⟨hal-03016039⟩
200 Consultations
476 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More