F. Verhaegen, P. Granton, and E. Tryggestad, Small animal radiotherapy research platforms, Phys Med Biol, vol.56, p.55, 2011.

K. T. Butterworth, K. M. Prise, and F. Verhaegen, Small animal image-guided radiotherapy : status, considerations and potential for translational impact, The British Journal of Radiology, vol.88, p.20140634, 1045.

M. Desrosiers, L. Dewerd, and . Deye, The Importance of Dosimetry Standardization in Radiobiology, J Res Nat Inst Stand Technol, vol.118, pp.403-418, 2013.

K. H. Pedersen, K. A. Kunugi, C. G. Hammer, W. S. Culberson, and L. A. Dewerd, Radiation biology irradiator dose verification survey, Radiat Res, vol.185, pp.163-168, 2016.

W. Ngwa, H. Korideck, L. M. Chin, G. M. Makrigiorgos, and R. I. Berbeco, MOSFET assessment of radiation dose delivered to mice using the small animal radiation research platform (SARRP)

, Radiat Res, vol.176, pp.816-820, 2011.

A. Anvari, Y. Poirier, and A. Sawant, Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP), Med. Phys, vol.45, issue.7, pp.3246-3257, 2018.

P. Kuess, E. Bozsaky, J. Hopfgartner, G. Seifritz, W. Dorr et al., Dosimetric challences of small animal irradiation with a commercial X-ray unit, Z Med. Phys, vol.24, issue.4, pp.363-372, 2018.

. International-atomic-energy and . Agency, Development of Procedures for In Vivo Dosimetry in Radiotherapy. No. 8 in IAEA, Human Health Reports. Vienna: INTERNA-TIONAL ATOMIC ENERGY AGENCY, 2013.

P. V. Granton, M. Podesta, G. Landry, S. Nijsten, G. Bootsma et al., A combined dose calculation and verification method for a small animal precision irradiator based on onboard imaging, Med. Phys, vol.39, issue.7, pp.4155-4166, 2012.

L. Beaulieu, L. Goulet, S. Archambault, and . Beddar, Current status of scintillation dosimetry for megavoltage beams, J Phys Conf Ser, vol.444, issue.1, p.12013, 2013.

A. S. Beddar, The 2nd Summer School on Solid State Dosimetry: Concepts and Trends in Medical Dosimetry, S124 { S133, vol.41, 2006.

P. Carrasco, N. Jornet, and O. Jordi, Characterization of the Exradin W1 scintillator for use in radiotherapy, Med. Phys, vol.42, issue.1, pp.297-304, 2015.

D. M. Klein, R. C. Tailor, L. Archambault, F. Therriault-proulx, and A. S. Beddar, Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors, Med. Phys, vol.37, issue.10, pp.5541-5549, 2010.

J. Morin, D. Béliveau-nadeau, and E. Chung, A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters : The case of the CyberKnife, Med. Phys, vol.40, issue.1, pp.11719-11730, 2013.

C. Johnstone, F. Therriault-proulx, L. Beaulieu, and M. Bazalova-carter, Characterization of a Plastic Scintillating Detector for the Small Animal Radiation Research Platform (SARRP)

, Med Phys, vol.46, issue.1, pp.394-404, 2018.

C. L. Deroff, A. Frelin-labalme, and X. Ledoux, Characterization of a scintillating fibre detector for small animal imaging and irradiation dosimetry, Br J Radiol, vol.90, p.20160454, 1069.
URL : https://hal.archives-ouvertes.fr/in2p3-01430231

C. L. Deroff, A. Frelin, and X. Ledoux, Energy dependence of a scintillating fiber detector for preclinical dosimetry with an image guided micro-irradiator, Phys Med Biol, 2019.
URL : https://hal.archives-ouvertes.fr/in2p3-02168308

P. E. Lindsay, P. V. Granton, and A. Gasparini, Multi-institutional dosimetric and geometric commissioning of image-guided small animal irradiators, Med. Phys, vol.41, issue.3, pp.31714-31725, 2014.

B. Walters, I. Kawrakow, and D. W. Rogers, DOSXYZnrc Users Manual

D. R. White, I. J. Wilson, J. Booz, J. J. Spokas, and R. V. Griffith, Journal of the International Commission on Radiation Units and Measurements, vol.44, 1989.

C. A. Schneider, W. S. Rasband, and K. W. Eliceiri, NIH Image to ImageJ: 25 years of image analysis, Nat Methods, vol.9, issue.7, p.5554542, 2012.

W. Lutz, K. R. Winston, and N. Maleki, A system for stereotactic radiosurgery with a linear accelerator, Int J Radiat Oncol Biol Phys, vol.14, issue.2, pp.373-81, 1988.

S. J. Van-hoof, P. V. Granton, and F. Verhaegen, Development and validation of a treatment planning system for small animal radiotherapy : SmART-Plan, Radiother Oncol, vol.109, issue.3, pp.361-366, 2013.

D. Sarrut, M. Bardiès, and N. , Boussion et al, A review of the use and potential of the GATE Monte Carlo code for radiation therapy and dosimetry applications, Med. Phys, vol.41, issue.6, p.64301, 2014.

C. Noblet, S. Chiavassa, and F. , Smekens et al, Validation of fast Monte Carlo dose calculation in small animal radiotherapy with EBT3 radiochromic films, Phys Med Biol, vol.61, issue.9, pp.3521-3556, 2016.

M. Bazalova and E. E. Graves, The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy, Med. Phys, vol.38, issue.6, pp.3039-3088, 2011.

C. Noblet, S. Chiavassa, F. Paris, S. Supiot, A. Lisbona et al., Underestimation of dose delivery in preclinical irradiation due to scattering conditions, Phys. Med, vol.30, issue.1, pp.63-71, 2014.

R. Hill, B. Healy, L. Holloway, Z. Kuncic, D. Thwaites et al., Advances in kilovoltage x-ray beam dosimetry, Phys Med Biol, vol.59, issue.6, pp.183-231, 2014.

J. Hubbell and S. Seltzer, Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption, 2019.

F. H. Attix, Introduction to radiological physics and radiation dosimetry, 1986.

A. Micke, D. F. Lewis, and X. Yu, Multichannel film dosimetry with non uniformity correction, Med Phys, vol.38, issue.5, pp.2523-2534, 2011.

, This work was supported by the French National Agency for Research n° ANR 10-EQPX-0014 and Cancéropôle Nord Ouest (Emergence grant)