Conduction mechanisms and voltage drop during field electron emission from diamond needles - Normandie Université Accéder directement au contenu
Article Dans Une Revue Ultramicroscopy Année : 2019

Conduction mechanisms and voltage drop during field electron emission from diamond needles

Résumé

We report results of experimental investigation of field electron emission from diamond nanoemitters. The measurements were performed with single crystal diamond needles fixed at tungsten tips. The voltage drop along diamond needles during emission was revealed and measured using electron energy spectroscopy. The observed linear dependence of the voltage drop in diamond on voltage applied to the tungsten tip is explained in the frame of a simple macroscopic electrical model combining Poole–Frenkel conduction along the diamond tip and Fowler–Nordheim tunneling at the diamond-vacuum junction. Experimental evidences of electron emission sensitivity to laser illumination are discussed for possible modification of diamond emitter characteristics and voltage drop.
Fichier principal
Vignette du fichier
S0304399118303930.pdf (1.26 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-02109685 , version 1 (22-10-2021)

Licence

Paternité - Pas d'utilisation commerciale

Identifiants

Citer

Olivier Torresin, Mario Borz, Julien Mauchain, Ivan Blum, Victor Kleshch, et al.. Conduction mechanisms and voltage drop during field electron emission from diamond needles. Ultramicroscopy, 2019, 202, pp.51-56. ⟨10.1016/j.ultramic.2019.03.006⟩. ⟨hal-02109685⟩
161 Consultations
89 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More